Soldering a CubeNode onto a PCB
To solder a CubeNode onto a PCB, you can do the following:
Prepare "no clean" soldering paste to remove the need for post-soldering PCB cleaning.
Prepare a convention-type soldering oven. This allows for more precise temperature control compared to an infrared-type radiation oven.
Configure the oven settings.
Take into account the following for the final soldering temperature:
Soldering paste type
Baseboard size, thickness, and material properties
Do not exceed the peak temperature of the recommended soldering profile.
Do not use a damp heat process during the soldering.
Bake the PCB.
Preheat the PCB to remove all the residual humidity using the following parameters:
Temperature rise rate: Max 3 °C/s
Time: 60 ~ 120 s
End temperature: 150 ~ 200 °C
Insufficient preheating causes large solder balls to be formed.
Excessive preheating can lead to both fine and large solder balls clustering.
Perform the heating-flow to the PCB with the following parameters:
Time limit above 217 °C liquidus temperature: 40 ~ 100s
Peak reflow temperature: 245 °C
Avoid sudden temperature increases to prevent solder paste slump.
Perform a controlled cooling process to cool the PCB with the following parameters:
Temperature fall rate: Max 4 °C/s
A controlled cooling process prevents the solder from becoming brittle.
It is recommended to conduct an optical inspection after the soldering.
PCB cleaning is recommended if a soldering paste other than "no-clean" was used.
Do not clean the PCB with the following:
Water (may cause short-circuits)
Alcohol or organic solvent (may leave inaccessible residues)
Ultrasonic cleaner (may cause permanent damage)
Last updated